A. O. Smith HPTA-66 2** Water Heater Specifications (3.84 UEF)
Certified at 3.84 UEF across its 68-gallon nominal tank, 83 gal First Hour Rating, A. O. Smith HPTA-66 2** (Hybrid/Electric Heat Pump, Electric) places #221 of 706 out of 706 ENERGY STAR models (PD 3417561). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.34 / +53.6%. Rated annual electricity draw of 1,292 kWh/yr equates to roughly $235/yr ($2,346 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPA10266H045DV 2** (3.84 UEF).
- Uniform Energy Factor
- 3.84 UEF
- Cohort UEF Rank
- #221 of 706 (top 32.4%)
- First Hour Rating
- 83 gal
- Storage Volume
- 68 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.34 / +53.6%

Tested at 3.84 UEF, A. O. Smith HPTA-66 2** places #221 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.14 UEF vs. 3.70 UEF median).
A. O. Smith HPTA-66 2** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.34 UEF (+53.6% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,292 kWh/yr for A. O. Smith HPTA-66 2** runs ~$235/yr vs. ~$979/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HPTA-66 2**: 10-year operating spend spans $1,890 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,096 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to A. O. Smith HPTA-66 2** include American HPA10266H045DV 2** (3.84 UEF, at parity) alongside Lochinvar CHPA-66 2** (3.84 UEF, at parity).
Where Does A. O. Smith HPTA-66 2** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, A. O. Smith HPTA-66 2** holds #221 of 706 (top 32.4%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 3417561 |
| Model Number | HPTA-66 2** | Draw pattern: High-Usage | HPTA-66 2** |
| Uniform Energy Factor (UEF) | 3.84 | +0.14 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 83 gal | +11 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,292 kWh/yr | +220 kWh/yr vs. 1,072 kWh/yr median | Est. $235/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
How Much Electricity Does HPTA-66 2** Use in Different States?
Estimated at $235/yr nationally (1,292 kWh/yr), 10-year utility spending for A. O. Smith HPTA-66 2** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $235/yr | $2,346 | $7,447 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $610/yr | $6,096 | $19,349 |
| California | 29.75 ¢/kWh ($0.2975) | $384/yr | $3,844 | $12,200 |
| Texas | 15.91 ¢/kWh ($0.1591) | $206/yr | $2,056 | $6,525 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $189/yr | $1,890 | $6,000 |
Does CPSC Flag Any Safety Notices on A. O. Smith Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning A. O. Smith; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPTA-66 2**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to A. O. Smith HPTA-66 2**'s gallon capacity and 3.84 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPA10266H045DV 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| Lochinvar CHPA-66 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| RELIANCE WATER HEATERS 10-66-DHPTA 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| State CSHP-66 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| Lochinvar HPPA065KD 2** | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
Who Is A. O. Smith HPTA-66 2** Best For — and When Should You Pick American HPA10266H045DV 2**?
Evaluate whether A. O. Smith HPTA-66 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- A. O. Smith HPTA-66 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTA-66 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for A. O. Smith HPTA-66 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does A. O. Smith HPTA-66 2** (3.84 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, A. O. Smith HPTA-66 2** records 3.84 UEF (Pass: +1.34 / +53.6%), placing #221 of 706 (top 32.4%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does A. O. Smith HPTA-66 2** fit inside a tight hallway closet or low-headroom utility room?
A. O. Smith HPTA-66 2** requires room for its 61 in. vertical shell and 23 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern A. O. Smith HPTA-66 2**?
For A. O. Smith HPTA-66 2**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for A. O. Smith HPTA-66 2**?
Using 1,292 kWh/yr, A. O. Smith HPTA-66 2** generates an estimated $235/yr electric bill at 18.16 cents/kWh (ranging from $189/yr in Washington hydro tiers up to $610/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of A. O. Smith HPTA-66 2** (3.84 UEF)?
A. O. Smith HPTA-66 2** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or American HPA10266H045DV 2**.
What hot-water delivery rating governs A. O. Smith HPTA-66 2**?
Rated for 83 gal FHR (+11 gal vs. 72 gal median), A. O. Smith HPTA-66 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen A. O. Smith HPTA-66 2** for recalls and tank age?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to A. O. Smith HPTA-66 2** in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is American HPA10266H045DV 2** (3.84 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)