A. O. Smith HPTV-80 2** Water Heater Specifications (3 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPTV-80 2** (Electric) achieves a certified 3.0 UEF rating across its 82-gallon nominal tank, 93 gal First Hour Rating (rank #666 of 706, PD 2546244) and verifies as Pass: +0.50 / +20.0% for 2029 DOE floors. Rated annual electricity draw of 1,654 kWh/yr equates to roughly $300/yr ($3,004 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPV10280H009DV 2** (3.0 UEF).
- Uniform Energy Factor
- 3.0 UEF
- Cohort UEF Rank
- #666 of 706
- First Hour Rating
- 93 gal
- Storage Volume
- 82 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.50 / +20.0%

A. O. Smith HPTV-80 2** records 3.0 UEF efficiency, putting it #666 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: A. O. Smith HPTV-80 2** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.50 UEF (+20.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,654 kWh/yr for A. O. Smith HPTV-80 2** runs ~$300/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).
State electric sensitivity for A. O. Smith HPTV-80 2**: 10-year operating spend spans $2,420 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,804 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside A. O. Smith HPTV-80 2** (3.0 UEF) are American HPV10280H009DV 2** (3.0 UEF, at parity) and Lochinvar HPV080KD 2** (3.0 UEF, at parity).
What Physical and Thermal Ratings Define A. O. Smith HPTV-80 2**?
Positioning at #666 of 706 out of 706 Hybrid/Electric Heat Pump peers, A. O. Smith HPTV-80 2** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2546244 |
| Model Number | HPTV-80 2** | Draw pattern: High-Usage | HPTV-80 2** |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 93 gal | +21 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,654 kWh/yr | +582 kWh/yr vs. 1,072 kWh/yr median | Est. $300/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 92" H x 27" D | Needs >72 in. overhead clearance; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 15 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 45 dBA | top 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
Why Do State Utility Rates Shift HPTV-80 2** Running Costs?
Consuming 1,654 kWh annually puts A. O. Smith HPTV-80 2** near $300/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $300/yr | $3,004 | $6,790 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $780/yr | $7,804 | $17,641 |
| California | 29.75 ¢/kWh ($0.2975) | $492/yr | $4,921 | $11,124 |
| Texas | 15.91 ¢/kWh ($0.1591) | $263/yr | $2,632 | $5,949 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $242/yr | $2,420 | $5,470 |
Have Any A. O. Smith Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to A. O. Smith HPTV-80 2**?
Homeowners cross-shopping A. O. Smith HPTV-80 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPV10280H009DV 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| Lochinvar HPV080KD 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| RELIANCE WATER HEATERS 10-80-DHPTV 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| State HPVX-80-DHPT 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| American HPHE10280H045DVCTA-1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (+0.45) | 1,387 |
Who Is A. O. Smith HPTV-80 2** Best For — and When Should You Pick American HPV10280H009DV 2**?
Evaluate whether A. O. Smith HPTV-80 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- A. O. Smith HPTV-80 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 45 dBA; avoid mounting A. O. Smith HPTV-80 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for A. O. Smith HPTV-80 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does A. O. Smith HPTV-80 2** (3.0 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, A. O. Smith HPTV-80 2** records 3.0 UEF (Pass: +0.50 / +20.0%), placing #666 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does A. O. Smith HPTV-80 2** fit inside a tight hallway closet or low-headroom utility room?
A. O. Smith HPTV-80 2** requires room for its 92 in. vertical shell and 27 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (27" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern A. O. Smith HPTV-80 2**?
For A. O. Smith HPTV-80 2**, plan a 120V circuit at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for A. O. Smith HPTV-80 2**?
Using 1,654 kWh/yr, A. O. Smith HPTV-80 2** generates an estimated $300/yr electric bill at 18.16 cents/kWh (ranging from $242/yr in Washington hydro tiers up to $780/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of A. O. Smith HPTV-80 2** (3.0 UEF)?
A. O. Smith HPTV-80 2** requires >=450 cu ft air space, 120V electrical supply, and drain access; tight interior alcoves favor ducted adapters or American HPV10280H009DV 2**.
What hot-water delivery rating governs A. O. Smith HPTV-80 2**?
Rated for 93 gal FHR (+21 gal vs. 72 gal median), A. O. Smith HPTV-80 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen A. O. Smith HPTV-80 2** for recalls and tank age?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to A. O. Smith HPTV-80 2** in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is American HPV10280H009DV 2** (3.0 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)