Skip to main content
ENERGY STAR water heater model · PD 2546244

A. O. Smith HPTV-80 2** Water Heater Specifications (3 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPTV-80 2** (Electric) achieves a certified 3.0 UEF rating across its 82-gallon nominal tank, 93 gal First Hour Rating (rank #666 of 706, PD 2546244) and verifies as Pass: +0.50 / +20.0% for 2029 DOE floors. Rated annual electricity draw of 1,654 kWh/yr equates to roughly $300/yr ($3,004 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPV10280H009DV 2** (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
93 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.50 / +20.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPTV-80 2** at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPTV-80 2**: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTV-80 2** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPTV-80 2** records 3.0 UEF efficiency, putting it #666 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: A. O. Smith HPTV-80 2** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.50 UEF (+20.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,654 kWh/yr for A. O. Smith HPTV-80 2** runs ~$300/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for A. O. Smith HPTV-80 2**: 10-year operating spend spans $2,420 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,804 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside A. O. Smith HPTV-80 2** (3.0 UEF) are American HPV10280H009DV 2** (3.0 UEF, at parity) and Lochinvar HPV080KD 2** (3.0 UEF, at parity).

What Physical and Thermal Ratings Define A. O. Smith HPTV-80 2**?

Positioning at #666 of 706 out of 706 Hybrid/Electric Heat Pump peers, A. O. Smith HPTV-80 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2546244
Model NumberHPTV-80 2**Draw pattern: High-UsageHPTV-80 2**
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)93 gal+21 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,654 kWh/yr+582 kWh/yr vs. 1,072 kWh/yr medianEst. $300/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency373%-56.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)92" H x 27" DNeeds >72 in. overhead clearance; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

Why Do State Utility Rates Shift HPTV-80 2** Running Costs?

Consuming 1,654 kWh annually puts A. O. Smith HPTV-80 2** near $300/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,654 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$300.00/yrHawaii$780.00/yrCalifornia$492.00/yrTexas$263.00/yrWashington$242.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $300/yr $3,004 $6,790
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $780/yr $7,804 $17,641
California 29.75 ¢/kWh ($0.2975) $492/yr $4,921 $11,124
Texas 15.91 ¢/kWh ($0.1591) $263/yr $2,632 $5,949
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $242/yr $2,420 $5,470
Estimated electricity spend (1,654 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any A. O. Smith Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to A. O. Smith HPTV-80 2**?

Homeowners cross-shopping A. O. Smith HPTV-80 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPV10280H009DV 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
Lochinvar HPV080KD 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
RELIANCE WATER HEATERS 10-80-DHPTV 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
State HPVX-80-DHPT 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
American HPHE10280H045DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (+0.45) 1,387

Who Is A. O. Smith HPTV-80 2** Best For — and When Should You Pick American HPV10280H009DV 2**?

Evaluate whether A. O. Smith HPTV-80 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • A. O. Smith HPTV-80 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting A. O. Smith HPTV-80 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPTV-80 2** Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPV10280H009DV 2** footprint.

Sizing, Efficiency & Recall Answers for A. O. Smith HPTV-80 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith HPTV-80 2** (3.0 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, A. O. Smith HPTV-80 2** records 3.0 UEF (Pass: +0.50 / +20.0%), placing #666 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does A. O. Smith HPTV-80 2** fit inside a tight hallway closet or low-headroom utility room?

A. O. Smith HPTV-80 2** requires room for its 92 in. vertical shell and 27 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (27" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern A. O. Smith HPTV-80 2**?

For A. O. Smith HPTV-80 2**, plan a 120V circuit at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for A. O. Smith HPTV-80 2**?

Using 1,654 kWh/yr, A. O. Smith HPTV-80 2** generates an estimated $300/yr electric bill at 18.16 cents/kWh (ranging from $242/yr in Washington hydro tiers up to $780/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of A. O. Smith HPTV-80 2** (3.0 UEF)?

A. O. Smith HPTV-80 2** requires >=450 cu ft air space, 120V electrical supply, and drain access; tight interior alcoves favor ducted adapters or American HPV10280H009DV 2**.

What hot-water delivery rating governs A. O. Smith HPTV-80 2**?

Rated for 93 gal FHR (+21 gal vs. 72 gal median), A. O. Smith HPTV-80 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen A. O. Smith HPTV-80 2** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to A. O. Smith HPTV-80 2** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is American HPV10280H009DV 2** (3.0 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks