ENERGY STAR water heater model · PD 2546253

Lochinvar HPV080KD 2** Water Heater Specifications (3 UEF)

With PD 2546253 certification, Lochinvar HPV080KD 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 82-gallon nominal tank, 93 gal First Hour Rating, standing #666 of 706 across 706 peers with Pass: +0.50 / +20.0% for May 6, 2029. Rated annual electricity draw of 1,654 kWh/yr equates to roughly $300/yr ($3,004 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTV-80 2** (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
93 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.50 / +20.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPV080KD 2** at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Lochinvar HPV080KD 2**: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPV080KD 2** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Lochinvar HPV080KD 2** at 3.0 UEF (#666 of 706; -0.70 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Lochinvar HPV080KD 2** stands +0.50 UEF (+20.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,654 kWh/yr for Lochinvar HPV080KD 2** runs ~$300/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Lochinvar HPV080KD 2**: 10-year operating spend spans $2,420 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,804 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HPTV-80 2** (3.0 UEF, at parity) and American HPV10280H009DV 2** (3.0 UEF, at parity) bracket Lochinvar HPV080KD 2**.

How Do Lochinvar HPV080KD 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

Lochinvar HPV080KD 2** places #666 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 2546253
Model NumberHPV080KD 2**Draw pattern: High-UsageHPV080KD 2**
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)93 gal+21 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,654 kWh/yr+582 kWh/yr vs. 1,072 kWh/yr medianEst. $300/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency373%-56.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)92" H x 27" DNeeds >72 in. overhead clearance; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

What Does HPV080KD 2** Cost to Operate Across State Electricity Rates?

At 1,654 kWh/yr, Lochinvar HPV080KD 2** runs roughly $300/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,654 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$300.00/yrHawaii$780.00/yrCalifornia$492.00/yrTexas$263.00/yrWashington$242.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $300/yr $3,004 $6,790
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $780/yr $7,804 $17,641
California 29.75 ¢/kWh ($0.2975) $492/yr $4,921 $11,124
Texas 15.91 ¢/kWh ($0.1591) $263/yr $2,632 $5,949
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $242/yr $2,420 $5,470
Estimated electricity spend (1,654 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Lochinvar Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 1 brand-level recall notice associated with Lochinvar; match your serial plate before repair. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Certified Water Heaters Match HPV080KD 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Lochinvar HPV080KD 2** by storage capacity and 3.0 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTV-80 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
American HPV10280H009DV 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
RELIANCE WATER HEATERS 10-80-DHPTV 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
State HPVX-80-DHPT 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
A. O. Smith HPV10-80H01DV 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654

When Should Homeowners Skip Lochinvar HPV080KD 2** (Hybrid/Electric Heat Pump)?

Check Lochinvar HPV080KD 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.50 / +20.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Lochinvar HPV080KD 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting Lochinvar HPV080KD 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPV080KD 2** Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTV-80 2** footprint.

What Are the Key Questions About Lochinvar HPV080KD 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Lochinvar HPV080KD 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.0 UEF, Lochinvar HPV080KD 2** shows Pass: +0.50 / +20.0% relative to May 6, 2029 federal DOE limits while placing #666 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPTV-80 2**.

Will Lochinvar HPV080KD 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 92 in. tall by 27 in. diameter, Lochinvar HPV080KD 2** notes: needs >72 in. overhead clearance; tight at 28 in. door (27" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Lochinvar HPV080KD 2** during replacement?

Electrical specs for Lochinvar HPV080KD 2** call for 120V at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Lochinvar HPV080KD 2**?

At 18.16 cents/kWh national residential pricing, Lochinvar HPV080KD 2**'s 1,654 kWh/yr draw equals roughly $300 annually or $3,000 across a 10-year horizon (ranging from $242/yr in Washington hydro tiers up to $780/yr in Hawaii).

When is Lochinvar HPV080KD 2** a poor fit for a residential replacement?

Avoid placing Lochinvar HPV080KD 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 45 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Lochinvar HPV080KD 2** deliver?

With 93 gal FHR (+21 gal vs. 72 gal median), Lochinvar HPV080KD 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Lochinvar HPV080KD 2**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Lochinvar HPV080KD 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Lochinvar HPV080KD 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTV-80 2** (3.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks