Skip to main content
ENERGY STAR water heater model · PD 2546245

State HPVX-80-DHPT 2** Water Heater Specifications (3 UEF)

The State HPVX-80-DHPT 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 82-gallon nominal tank, 93 gal First Hour Rating, ranking #666 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2546245). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.50 / +20.0%. Rated annual electricity draw of 1,654 kWh/yr equates to roughly $300/yr ($3,004 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTV-80 2** (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
93 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.50 / +20.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State HPVX-80-DHPT 2** at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50State HPVX-80-DHPT 2**: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPVX-80-DHPT 2** relative to the cohort median.
Efficiency comparison & rule summary

State HPVX-80-DHPT 2** (3.0 UEF) ranks #666 of 706 Hybrid/Electric Heat Pump models — 28-way tie; more efficient than 1.8% of Hybrid/Electric Heat Pump models, -0.70 UEF below the 3.70 UEF median.

Federal 2029 margin for State HPVX-80-DHPT 2**: +0.50 UEF (+20.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,654 kWh/yr for State HPVX-80-DHPT 2** runs ~$300/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for State HPVX-80-DHPT 2**: 10-year operating spend spans $2,420 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,804 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: State HPVX-80-DHPT 2** (3.0 UEF) compares closely with A. O. Smith HPTV-80 2** (3.0 UEF, at parity) and American HPV10280H009DV 2** (3.0 UEF, at parity).

What Physical and Thermal Ratings Define State HPVX-80-DHPT 2**?

Positioning at #666 of 706 out of 706 Hybrid/Electric Heat Pump peers, State HPVX-80-DHPT 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 2546245
Model NumberHPVX-80-DHPT 2**Draw pattern: High-UsageHPVX-80-DHPT 2**
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)93 gal+21 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,654 kWh/yr+582 kWh/yr vs. 1,072 kWh/yr medianEst. $300/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency373%-56.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)92" H x 27" DNeeds >72 in. overhead clearance; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

Why Do State Utility Rates Shift HPVX-80-DHPT 2** Running Costs?

Consuming 1,654 kWh annually puts State HPVX-80-DHPT 2** near $300/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,654 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$300.00/yrHawaii$780.00/yrCalifornia$492.00/yrTexas$263.00/yrWashington$242.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $300/yr $3,004 $6,790
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $780/yr $7,804 $17,641
California 29.75 ¢/kWh ($0.2975) $492/yr $4,921 $11,124
Texas 15.91 ¢/kWh ($0.1591) $263/yr $2,632 $5,949
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $242/yr $2,420 $5,470
Estimated electricity spend (1,654 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any State Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under State; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

What Are 5 Direct Alternatives to State HPVX-80-DHPT 2**?

Homeowners cross-shopping State HPVX-80-DHPT 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTV-80 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
American HPV10280H009DV 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
Lochinvar HPV080KD 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
RELIANCE WATER HEATERS 10-80-DHPTV 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654
A. O. Smith HPV10-80H01DV 2** Hybrid/Electric Heat Pump 82 gal 93 gal 3.0 (at parity) 1,654

What Installation Caveats Apply Before Buying State HPVX-80-DHPT 2**?

Even high-UEF units like State HPVX-80-DHPT 2** (3.0 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • State HPVX-80-DHPT 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting State HPVX-80-DHPT 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State HPVX-80-DHPT 2** Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTV-80 2** footprint.

Sizing, Efficiency & Recall Answers for State HPVX-80-DHPT 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is State HPVX-80-DHPT 2** eligible for continued manufacture past May 6, 2029?

At 3.0 UEF, State HPVX-80-DHPT 2** achieves Pass: +0.50 / +20.0% for the 2029 DOE standard and stands #666 of 706 against A. O. Smith HPTV-80 2** and American HPV10280H009DV 2**.

How tall and wide is State HPVX-80-DHPT 2**, and what service clearance is needed?

Physical dimensions for State HPVX-80-DHPT 2** are 92 in. height and 27 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (27" d)); verify stair turns and drain pan width before delivery.

Will State HPVX-80-DHPT 2** require upgrading household electrical panels or gas piping?

State HPVX-80-DHPT 2** draws 120V at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is State HPVX-80-DHPT 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $300/yr ($3,000 over 10 years) to power State HPVX-80-DHPT 2** at 1,654 kWh/yr under the 18.16 cents/kWh US average (ranging from $242/yr in Washington hydro tiers up to $780/yr in Hawaii).

Which installation bottlenecks limit State HPVX-80-DHPT 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, State HPVX-80-DHPT 2** drops into resistance mode more often.

How does State HPVX-80-DHPT 2** handle simultaneous showers and laundry?

Delivering 93 gal in the first hour (+21 gal vs. 72 gal median), State HPVX-80-DHPT 2** combines 82 gal tank storage with rapid burner/element recovery.

How long is the warranty on State HPVX-80-DHPT 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying State HPVX-80-DHPT 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTV-80 2** (3.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks