American HPV10280H009DV 2** Water Heater Specifications (3 UEF)
Certified at 3.0 UEF across its 82-gallon nominal tank, 93 gal First Hour Rating, American HPV10280H009DV 2** (Hybrid/Electric Heat Pump, Electric) places #666 of 706 out of 706 ENERGY STAR models (PD 2546246). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.50 / +20.0%. Rated annual electricity draw of 1,654 kWh/yr equates to roughly $300/yr ($3,004 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTV-80 2** (3.0 UEF).
- Uniform Energy Factor
- 3.0 UEF
- Cohort UEF Rank
- #666 of 706
- First Hour Rating
- 93 gal
- Storage Volume
- 82 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.50 / +20.0%

Tested at 3.0 UEF, American HPV10280H009DV 2** places #666 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.70 UEF vs. 3.70 UEF median).
American HPV10280H009DV 2** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.50 UEF (+20.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,654 kWh/yr for American HPV10280H009DV 2** runs ~$300/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).
State electric sensitivity for American HPV10280H009DV 2**: 10-year operating spend spans $2,420 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,804 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to American HPV10280H009DV 2** include A. O. Smith HPTV-80 2** (3.0 UEF, at parity) alongside Lochinvar HPV080KD 2** (3.0 UEF, at parity).
Where Does American HPV10280H009DV 2** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, American HPV10280H009DV 2** holds #666 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2546246 |
| Model Number | HPV10280H009DV 2** | Draw pattern: High-Usage | HPV10280H009DV 2** |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 93 gal | +21 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,654 kWh/yr | +582 kWh/yr vs. 1,072 kWh/yr median | Est. $300/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 92" H x 27" D | Needs >72 in. overhead clearance; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 15 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 45 dBA | top 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
How Much Electricity Does HPV10280H009DV 2** Use in Different States?
Estimated at $300/yr nationally (1,654 kWh/yr), 10-year utility spending for American HPV10280H009DV 2** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $300/yr | $3,004 | $6,790 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $780/yr | $7,804 | $17,641 |
| California | 29.75 ¢/kWh ($0.2975) | $492/yr | $4,921 | $11,124 |
| Texas | 15.91 ¢/kWh ($0.1591) | $263/yr | $2,632 | $5,949 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $242/yr | $2,420 | $5,470 |
Does CPSC Flag Any Safety Notices on American Units?
Checking 2026-11-23 SaferProducts data shows 2 notices mentioning American; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPV10280H009DV 2**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to American HPV10280H009DV 2**'s gallon capacity and 3.0 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPTV-80 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| Lochinvar HPV080KD 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| RELIANCE WATER HEATERS 10-80-DHPTV 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| State HPVX-80-DHPT 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| A. O. Smith HPV10-80H01DV 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
When Should Homeowners Skip American HPV10280H009DV 2** (Hybrid/Electric Heat Pump)?
Check American HPV10280H009DV 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.50 / +20.0% status—against typical residential installations.
Key Limitations & Exclusions
- American HPV10280H009DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 45 dBA; avoid mounting American HPV10280H009DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for American HPV10280H009DV 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will American HPV10280H009DV 2** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.0 UEF, American HPV10280H009DV 2** shows Pass: +0.50 / +20.0% relative to May 6, 2029 federal DOE limits while placing #666 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPTV-80 2**.
Will American HPV10280H009DV 2** fit through a standard utility door and 72-inch basement ceiling?
Measuring 92 in. tall by 27 in. diameter, American HPV10280H009DV 2** notes: needs >72 in. overhead clearance; tight at 28 in. door (27" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support American HPV10280H009DV 2** during replacement?
Electrical specs for American HPV10280H009DV 2** call for 120V at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for American HPV10280H009DV 2**?
At 18.16 cents/kWh national residential pricing, American HPV10280H009DV 2**'s 1,654 kWh/yr draw equals roughly $300 annually or $3,000 across a 10-year horizon (ranging from $242/yr in Washington hydro tiers up to $780/yr in Hawaii).
When is American HPV10280H009DV 2** a poor fit for a residential replacement?
Avoid placing American HPV10280H009DV 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 45 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does American HPV10280H009DV 2** deliver?
With 93 gal FHR (+21 gal vs. 72 gal median), American HPV10280H009DV 2** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on American HPV10280H009DV 2**?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does American HPV10280H009DV 2** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American HPV10280H009DV 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTV-80 2** (3.0 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)