A. O. Smith HPV10-80H01DV 2** Water Heater Specifications (3 UEF)
With PD 2546243 certification, A. O. Smith HPV10-80H01DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 82-gallon nominal tank, 93 gal First Hour Rating, standing #666 of 706 across 706 peers with Pass: +0.50 / +20.0% for May 6, 2029. Rated annual electricity draw of 1,654 kWh/yr equates to roughly $300/yr ($3,004 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPV10280H009DV 2** (3.0 UEF).
- Uniform Energy Factor
- 3.0 UEF
- Cohort UEF Rank
- #666 of 706
- First Hour Rating
- 93 gal
- Storage Volume
- 82 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.50 / +20.0%

ENERGY STAR certification places A. O. Smith HPV10-80H01DV 2** at 3.0 UEF (#666 of 706; -0.70 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: A. O. Smith HPV10-80H01DV 2** stands +0.50 UEF (+20.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,654 kWh/yr for A. O. Smith HPV10-80H01DV 2** runs ~$300/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).
State electric sensitivity for A. O. Smith HPV10-80H01DV 2**: 10-year operating spend spans $2,420 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,804 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, American HPV10280H009DV 2** (3.0 UEF, at parity) and Lochinvar HPV080KD 2** (3.0 UEF, at parity) bracket A. O. Smith HPV10-80H01DV 2**.
How Do A. O. Smith HPV10-80H01DV 2** Specs Compare to Hybrid/Electric Heat Pump Medians?
A. O. Smith HPV10-80H01DV 2** places #666 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2546243 |
| Model Number | HPV10-80H01DV 2** | Draw pattern: High-Usage | HPV10-80H01DV 2** |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 93 gal | +21 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,654 kWh/yr | +582 kWh/yr vs. 1,072 kWh/yr median | Est. $300/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 92" H x 27" D | Needs >72 in. overhead clearance; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 15 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 45 dBA | top 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
What Does HPV10-80H01DV 2** Cost to Operate Across State Electricity Rates?
At 1,654 kWh/yr, A. O. Smith HPV10-80H01DV 2** runs roughly $300/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $300/yr | $3,004 | $6,790 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $780/yr | $7,804 | $17,641 |
| California | 29.75 ¢/kWh ($0.2975) | $492/yr | $4,921 | $11,124 |
| Texas | 15.91 ¢/kWh ($0.1591) | $263/yr | $2,632 | $5,949 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $242/yr | $2,420 | $5,470 |
Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match HPV10-80H01DV 2** Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith HPV10-80H01DV 2** by storage capacity and 3.0 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPV10280H009DV 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| Lochinvar HPV080KD 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| RELIANCE WATER HEATERS 10-80-DHPTV 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| State HPVX-80-DHPT 2** | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| American HPHE10280H045DVCTA-1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (+0.45) | 1,387 |
What Are the Limitations of A. O. Smith HPV10-80H01DV 2** and Who Should Not Install It?
Before ordering A. O. Smith HPV10-80H01DV 2** (Hybrid/Electric Heat Pump, 3.0 UEF), weigh space clearances, fuel piping, noise (45 dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- A. O. Smith HPV10-80H01DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 45 dBA; avoid mounting A. O. Smith HPV10-80H01DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About A. O. Smith HPV10-80H01DV 2**?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does A. O. Smith HPV10-80H01DV 2** pass the May 6, 2029 federal DOE efficiency rule?
A. O. Smith HPV10-80H01DV 2** carries a verified 3.0 UEF rating (Pass: +0.50 / +20.0%), ranking #666 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does A. O. Smith HPV10-80H01DV 2** need?
A. O. Smith HPV10-80H01DV 2** stands 92 in. high with a 27 in. diameter; needs >72 in. overhead clearance; tight at 28 in. door (27" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does A. O. Smith HPV10-80H01DV 2** require?
A. O. Smith HPV10-80H01DV 2** uses a 120V branch circuit at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does A. O. Smith HPV10-80H01DV 2** cost per year to run?
Rated at 1,654 kWh/yr, A. O. Smith HPV10-80H01DV 2** costs about $300/yr ($3,000 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $242/yr in Washington hydro tiers up to $780/yr in Hawaii).
Who should NOT install A. O. Smith HPV10-80H01DV 2**, and what are its limits?
A. O. Smith HPV10-80H01DV 2** (3.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 45 dBA.
How many bathrooms or people can A. O. Smith HPV10-80H01DV 2** serve at peak demand?
A. O. Smith HPV10-80H01DV 2** achieves a 93 gal First Hour Rating (+21 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for A. O. Smith HPV10-80H01DV 2**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to A. O. Smith HPV10-80H01DV 2**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is American HPV10280H009DV 2** (3.0 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)