American HPS10266H045DV 2** Water Heater Specifications (3.7 UEF)

The American HPS10266H045DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating, ranking #347 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408850). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.20 / +48.0%. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
82 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American HPS10266H045DV 2** at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50American HPS10266H045DV 2**: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPS10266H045DV 2** relative to the cohort median.
Efficiency comparison & rule summary

American HPS10266H045DV 2** (3.7 UEF) ranks #347 of 706 Hybrid/Electric Heat Pump models — 42-way tie; more efficient than 45% of Hybrid/Electric Heat Pump models, at the 3.70 UEF median.

Federal 2029 margin for American HPS10266H045DV 2**: +1.20 UEF (+48.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for American HPS10266H045DV 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPS10266H045DV 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: American HPS10266H045DV 2** (3.7 UEF) compares closely with A. O. Smith HPS10-66H45DV 2** (3.7 UEF, at parity) and Lochinvar HPSA065KD 2** (3.7 UEF, at parity).

What Physical and Thermal Ratings Define American HPS10266H045DV 2**?

Positioning at #347 of 706 out of 706 Hybrid/Electric Heat Pump peers, American HPS10266H045DV 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408850
Model NumberHPS10266H045DV 2**Draw pattern: High-UsageHPS10266H045DV 2**
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,233 kWh/yr+161 kWh/yr vs. 1,072 kWh/yr medianEst. $224/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency425%-4.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

Why Do State Utility Rates Shift HPS10266H045DV 2** Running Costs?

Consuming 1,233 kWh annually puts American HPS10266H045DV 2** near $224/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,233 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$224.00/yrHawaii$582.00/yrCalifornia$367.00/yrTexas$196.00/yrWashington$180.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $224/yr $2,239 $6,766
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $582/yr $5,817 $17,579
California 29.75 ¢/kWh ($0.2975) $367/yr $3,668 $11,085
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,962 $5,928
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $180/yr $1,804 $5,451
Estimated electricity spend (1,233 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any American Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to American HPS10266H045DV 2**?

Homeowners cross-shopping American HPS10266H045DV 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPS10-66H45DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
Lochinvar HPSA065KD 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
RELIANCE WATER HEATERS 10-66-DHPTS 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
State HPSX-66-DHPT 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
A. O. Smith HPSN10-66H45DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233

When Should Homeowners Skip American HPS10266H045DV 2** (Hybrid/Electric Heat Pump)?

Check American HPS10266H045DV 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.

Key Limitations & Exclusions

  • American HPS10266H045DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American HPS10266H045DV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American HPS10266H045DV 2** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPS10-66H45DV 2** footprint.

Sizing, Efficiency & Recall Answers for American HPS10266H045DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will American HPS10266H045DV 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.7 UEF, American HPS10266H045DV 2** shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPS10-66H45DV 2**.

Will American HPS10266H045DV 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 61 in. tall by 23 in. diameter, American HPS10266H045DV 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support American HPS10266H045DV 2** during replacement?

Electrical specs for American HPS10266H045DV 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for American HPS10266H045DV 2**?

At 18.16 cents/kWh national residential pricing, American HPS10266H045DV 2**'s 1,233 kWh/yr draw equals roughly $224 annually or $2,240 across a 10-year horizon (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii).

When is American HPS10266H045DV 2** a poor fit for a residential replacement?

Avoid placing American HPS10266H045DV 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does American HPS10266H045DV 2** deliver?

With 82 gal FHR (+10 gal vs. 72 gal median), American HPS10266H045DV 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on American HPS10266H045DV 2**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does American HPS10266H045DV 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American HPS10266H045DV 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks