American HPS10266H045DV 2** Water Heater Specifications (3.7 UEF)
The American HPS10266H045DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating, ranking #347 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408850). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.20 / +48.0%. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).
- Uniform Energy Factor
- 3.7 UEF
- Cohort UEF Rank
- #347 of 706
- First Hour Rating
- 82 gal
- Storage Volume
- 67 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +48.0%

American HPS10266H045DV 2** (3.7 UEF) ranks #347 of 706 Hybrid/Electric Heat Pump models — 42-way tie; more efficient than 45% of Hybrid/Electric Heat Pump models, at the 3.70 UEF median.
Federal 2029 margin for American HPS10266H045DV 2**: +1.20 UEF (+48.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for American HPS10266H045DV 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.
State electric sensitivity for American HPS10266H045DV 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: American HPS10266H045DV 2** (3.7 UEF) compares closely with A. O. Smith HPS10-66H45DV 2** (3.7 UEF, at parity) and Lochinvar HPSA065KD 2** (3.7 UEF, at parity).
What Physical and Thermal Ratings Define American HPS10266H045DV 2**?
Positioning at #347 of 706 out of 706 Hybrid/Electric Heat Pump peers, American HPS10266H045DV 2** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408850 |
| Model Number | HPS10266H045DV 2** | Draw pattern: High-Usage | HPS10266H045DV 2** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,233 kWh/yr | +161 kWh/yr vs. 1,072 kWh/yr median | Est. $224/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 425% | -4.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
Why Do State Utility Rates Shift HPS10266H045DV 2** Running Costs?
Consuming 1,233 kWh annually puts American HPS10266H045DV 2** near $224/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $224/yr | $2,239 | $6,766 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $582/yr | $5,817 | $17,579 |
| California | 29.75 ¢/kWh ($0.2975) | $367/yr | $3,668 | $11,085 |
| Texas | 15.91 ¢/kWh ($0.1591) | $196/yr | $1,962 | $5,928 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $180/yr | $1,804 | $5,451 |
Have Any American Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to American HPS10266H045DV 2**?
Homeowners cross-shopping American HPS10266H045DV 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPS10-66H45DV 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| Lochinvar HPSA065KD 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| RELIANCE WATER HEATERS 10-66-DHPTS 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| State HPSX-66-DHPT 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| A. O. Smith HPSN10-66H45DV 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
When Should Homeowners Skip American HPS10266H045DV 2** (Hybrid/Electric Heat Pump)?
Check American HPS10266H045DV 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.
Key Limitations & Exclusions
- American HPS10266H045DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPS10266H045DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for American HPS10266H045DV 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will American HPS10266H045DV 2** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.7 UEF, American HPS10266H045DV 2** shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPS10-66H45DV 2**.
Will American HPS10266H045DV 2** fit through a standard utility door and 72-inch basement ceiling?
Measuring 61 in. tall by 23 in. diameter, American HPS10266H045DV 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support American HPS10266H045DV 2** during replacement?
Electrical specs for American HPS10266H045DV 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for American HPS10266H045DV 2**?
At 18.16 cents/kWh national residential pricing, American HPS10266H045DV 2**'s 1,233 kWh/yr draw equals roughly $224 annually or $2,240 across a 10-year horizon (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii).
When is American HPS10266H045DV 2** a poor fit for a residential replacement?
Avoid placing American HPS10266H045DV 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does American HPS10266H045DV 2** deliver?
With 82 gal FHR (+10 gal vs. 72 gal median), American HPS10266H045DV 2** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on American HPS10266H045DV 2**?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does American HPS10266H045DV 2** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American HPS10266H045DV 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)