A. O. Smith HPSN10-66H45DV 2** Water Heater Specifications (3.7 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPSN10-66H45DV 2** (Electric) achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating (rank #347 of 706, PD 4015934) and verifies as Pass: +1.20 / +48.0% for 2029 DOE floors. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPS10266H045DV 2** (3.7 UEF).
- Uniform Energy Factor
- 3.7 UEF
- Cohort UEF Rank
- #347 of 706
- First Hour Rating
- 82 gal
- Storage Volume
- 67 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +48.0%

A. O. Smith HPSN10-66H45DV 2** records 3.7 UEF efficiency, putting it #347 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: A. O. Smith HPSN10-66H45DV 2** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.20 UEF (+48.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for A. O. Smith HPSN10-66H45DV 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HPSN10-66H45DV 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside A. O. Smith HPSN10-66H45DV 2** (3.7 UEF) are American HPS10266H045DV 2** (3.7 UEF, at parity) and Lochinvar HPSA065KD 2** (3.7 UEF, at parity).
What Physical and Thermal Ratings Define A. O. Smith HPSN10-66H45DV 2**?
Positioning at #347 of 706 out of 706 Hybrid/Electric Heat Pump peers, A. O. Smith HPSN10-66H45DV 2** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 4015934 |
| Model Number | HPSN10-66H45DV 2** | Draw pattern: High-Usage | HPSN10-66H45DV 2** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,233 kWh/yr | +161 kWh/yr vs. 1,072 kWh/yr median | Est. $224/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 425% | -4.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
Why Do State Utility Rates Shift HPSN10-66H45DV 2** Running Costs?
Consuming 1,233 kWh annually puts A. O. Smith HPSN10-66H45DV 2** near $224/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $224/yr | $2,239 | $6,766 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $582/yr | $5,817 | $17,579 |
| California | 29.75 ¢/kWh ($0.2975) | $367/yr | $3,668 | $11,085 |
| Texas | 15.91 ¢/kWh ($0.1591) | $196/yr | $1,962 | $5,928 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $180/yr | $1,804 | $5,451 |
Have Any A. O. Smith Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to A. O. Smith HPSN10-66H45DV 2**?
Homeowners cross-shopping A. O. Smith HPSN10-66H45DV 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPS10266H045DV 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| Lochinvar HPSA065KD 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| RELIANCE WATER HEATERS 10-66-DHPTS 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| State HPSX-66-DHPT 2** | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| American HPHE10266H045DVCTA-1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (-0.25) | 1,381 |
What Are the Limitations of A. O. Smith HPSN10-66H45DV 2** and Who Should Not Install It?
Before ordering A. O. Smith HPSN10-66H45DV 2** (Hybrid/Electric Heat Pump, 3.7 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- A. O. Smith HPSN10-66H45DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPSN10-66H45DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for A. O. Smith HPSN10-66H45DV 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does A. O. Smith HPSN10-66H45DV 2** pass the May 6, 2029 federal DOE efficiency rule?
A. O. Smith HPSN10-66H45DV 2** carries a verified 3.7 UEF rating (Pass: +1.20 / +48.0%), ranking #347 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does A. O. Smith HPSN10-66H45DV 2** need?
A. O. Smith HPSN10-66H45DV 2** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does A. O. Smith HPSN10-66H45DV 2** require?
A. O. Smith HPSN10-66H45DV 2** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does A. O. Smith HPSN10-66H45DV 2** cost per year to run?
Rated at 1,233 kWh/yr, A. O. Smith HPSN10-66H45DV 2** costs about $224/yr ($2,240 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii).
Who should NOT install A. O. Smith HPSN10-66H45DV 2**, and what are its limits?
A. O. Smith HPSN10-66H45DV 2** (3.7 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can A. O. Smith HPSN10-66H45DV 2** serve at peak demand?
A. O. Smith HPSN10-66H45DV 2** achieves a 82 gal First Hour Rating (+10 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for A. O. Smith HPSN10-66H45DV 2**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to A. O. Smith HPSN10-66H45DV 2**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is American HPS10266H045DV 2** (3.7 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)