Skip to main content
ENERGY STAR water heater model · PD 2408836

Lochinvar HPSA065KD 2** Water Heater Specifications (3.7 UEF)

Certified at 3.7 UEF across its 67-gallon nominal tank, 82 gal First Hour Rating, Lochinvar HPSA065KD 2** (Hybrid/Electric Heat Pump, Electric) places #347 of 706 out of 706 ENERGY STAR models (PD 2408836). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.20 / +48.0%. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
82 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPSA065KD 2** at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Lochinvar HPSA065KD 2**: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPSA065KD 2** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.7 UEF, Lochinvar HPSA065KD 2** places #347 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (At 3.70 UEF median).

Lochinvar HPSA065KD 2** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.20 UEF (+48.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for Lochinvar HPSA065KD 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar HPSA065KD 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Lochinvar HPSA065KD 2** include A. O. Smith HPS10-66H45DV 2** (3.7 UEF, at parity) alongside American HPS10266H045DV 2** (3.7 UEF, at parity).

Where Does Lochinvar HPSA065KD 2** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Lochinvar HPSA065KD 2** holds #347 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 2408836
Model NumberHPSA065KD 2**Draw pattern: High-UsageHPSA065KD 2**
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,233 kWh/yr+161 kWh/yr vs. 1,072 kWh/yr medianEst. $224/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency425%-4.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Much Electricity Does HPSA065KD 2** Use in Different States?

Estimated at $224/yr nationally (1,233 kWh/yr), 10-year utility spending for Lochinvar HPSA065KD 2** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,233 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$224.00/yrHawaii$582.00/yrCalifornia$367.00/yrTexas$196.00/yrWashington$180.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $224/yr $2,239 $6,766
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $582/yr $5,817 $17,579
California 29.75 ¢/kWh ($0.2975) $367/yr $3,668 $11,085
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,962 $5,928
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $180/yr $1,804 $5,451
Estimated electricity spend (1,233 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Lochinvar Units?

Checking 2026-11-23 SaferProducts data shows 1 notice mentioning Lochinvar; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPSA065KD 2**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Lochinvar HPSA065KD 2**'s gallon capacity and 3.7 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPS10-66H45DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
American HPS10266H045DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
RELIANCE WATER HEATERS 10-66-DHPTS 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
State HPSX-66-DHPT 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
A. O. Smith HPSN10-66H45DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233

When Should Homeowners Skip Lochinvar HPSA065KD 2** (Hybrid/Electric Heat Pump)?

Check Lochinvar HPSA065KD 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Lochinvar HPSA065KD 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar HPSA065KD 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPSA065KD 2** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPS10-66H45DV 2** footprint.

Common Homeowner Questions for Lochinvar HPSA065KD 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Lochinvar HPSA065KD 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.7 UEF, Lochinvar HPSA065KD 2** shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPS10-66H45DV 2**.

Will Lochinvar HPSA065KD 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 61 in. tall by 23 in. diameter, Lochinvar HPSA065KD 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Lochinvar HPSA065KD 2** during replacement?

Electrical specs for Lochinvar HPSA065KD 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Lochinvar HPSA065KD 2**?

At 18.16 cents/kWh national residential pricing, Lochinvar HPSA065KD 2**'s 1,233 kWh/yr draw equals roughly $224 annually or $2,240 across a 10-year horizon (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii).

When is Lochinvar HPSA065KD 2** a poor fit for a residential replacement?

Avoid placing Lochinvar HPSA065KD 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Lochinvar HPSA065KD 2** deliver?

With 82 gal FHR (+10 gal vs. 72 gal median), Lochinvar HPSA065KD 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Lochinvar HPSA065KD 2**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Lochinvar HPSA065KD 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Lochinvar HPSA065KD 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks