State HPSX-66-DHPT 2** Water Heater Specifications (3.7 UEF)

With PD 2408843 certification, State HPSX-66-DHPT 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating, standing #347 of 706 across 706 peers with Pass: +1.20 / +48.0% for May 6, 2029. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
82 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State HPSX-66-DHPT 2** at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50State HPSX-66-DHPT 2**: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPSX-66-DHPT 2** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places State HPSX-66-DHPT 2** at 3.7 UEF (#347 of 706; At 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: State HPSX-66-DHPT 2** stands +1.20 UEF (+48.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for State HPSX-66-DHPT 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HPSX-66-DHPT 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HPS10-66H45DV 2** (3.7 UEF, at parity) and American HPS10266H045DV 2** (3.7 UEF, at parity) bracket State HPSX-66-DHPT 2**.

Which Specs Set State HPSX-66-DHPT 2** Apart From Cohort Averages?

Ranked #347 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, State HPSX-66-DHPT 2** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 2408843
Model NumberHPSX-66-DHPT 2**Draw pattern: High-UsageHPSX-66-DHPT 2**
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,233 kWh/yr+161 kWh/yr vs. 1,072 kWh/yr medianEst. $224/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency425%-4.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Do Regional kWh Prices Impact HPSX-66-DHPT 2** Over 10 Years?

Using EIA Table 5.6.A benchmarks, State HPSX-66-DHPT 2**'s 1,233 kWh/yr draw translates to roughly $224/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,233 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$224.00/yrHawaii$582.00/yrCalifornia$367.00/yrTexas$196.00/yrWashington$180.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $224/yr $2,239 $6,766
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $582/yr $5,817 $17,579
California 29.75 ¢/kWh ($0.2975) $367/yr $3,668 $11,085
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,962 $5,928
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $180/yr $1,804 $5,451
Estimated electricity spend (1,233 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should State Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to State; verify whether your HPSX-66-DHPT 2** production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPS10-66H45DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
American HPS10266H045DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
Lochinvar HPSA065KD 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
RELIANCE WATER HEATERS 10-66-DHPTS 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
A. O. Smith HPSN10-66H45DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233

What Are the Limitations of State HPSX-66-DHPT 2** and Who Should Not Install It?

Before ordering State HPSX-66-DHPT 2** (Hybrid/Electric Heat Pump, 3.7 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • State HPSX-66-DHPT 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State HPSX-66-DHPT 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State HPSX-66-DHPT 2** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPS10-66H45DV 2** footprint.

Frequently Asked Technical Questions: State HPSX-66-DHPT 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does State HPSX-66-DHPT 2** pass the May 6, 2029 federal DOE efficiency rule?

State HPSX-66-DHPT 2** carries a verified 3.7 UEF rating (Pass: +1.20 / +48.0%), ranking #347 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does State HPSX-66-DHPT 2** need?

State HPSX-66-DHPT 2** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does State HPSX-66-DHPT 2** require?

State HPSX-66-DHPT 2** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does State HPSX-66-DHPT 2** cost per year to run?

Rated at 1,233 kWh/yr, State HPSX-66-DHPT 2** costs about $224/yr ($2,240 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii).

Who should NOT install State HPSX-66-DHPT 2**, and what are its limits?

State HPSX-66-DHPT 2** (3.7 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can State HPSX-66-DHPT 2** serve at peak demand?

State HPSX-66-DHPT 2** achieves a 82 gal First Hour Rating (+10 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for State HPSX-66-DHPT 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to State HPSX-66-DHPT 2**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)