Skip to main content
ENERGY STAR water heater model · PD 2408837

RELIANCE WATER HEATERS 10-66-DHPTS 2** Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, RELIANCE WATER HEATERS 10-66-DHPTS 2** achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 2408837), recording Pass: +1.20 / +48.0% under 2029 DOE rules. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
82 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking RELIANCE WATER HEATERS 10-66-DHPTS 2** at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50RELIANCE WATER HEATERS 10-66-DHPTS 2**: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 10-66-DHPTS 2** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, RELIANCE WATER HEATERS 10-66-DHPTS 2** logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), RELIANCE WATER HEATERS 10-66-DHPTS 2** holds a +1.20 UEF (+48.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for RELIANCE WATER HEATERS 10-66-DHPTS 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS 10-66-DHPTS 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping RELIANCE WATER HEATERS 10-66-DHPTS 2** (3.7 UEF)? Check A. O. Smith HPS10-66H45DV 2** (3.7 UEF, at parity) and American HPS10266H045DV 2** (3.7 UEF, at parity).

How Do RELIANCE WATER HEATERS 10-66-DHPTS 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

RELIANCE WATER HEATERS 10-66-DHPTS 2** places #347 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 2408837
Model Number10-66-DHPTS 2**Draw pattern: High-Usage10-66-DHPTS 2**
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,233 kWh/yr+161 kWh/yr vs. 1,072 kWh/yr medianEst. $224/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency425%-4.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

What Does 10-66-DHPTS 2** Cost to Operate Across State Electricity Rates?

At 1,233 kWh/yr, RELIANCE WATER HEATERS 10-66-DHPTS 2** runs roughly $224/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,233 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$224.00/yrHawaii$582.00/yrCalifornia$367.00/yrTexas$196.00/yrWashington$180.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $224/yr $2,239 $6,766
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $582/yr $5,817 $17,579
California 29.75 ¢/kWh ($0.2975) $367/yr $3,668 $11,085
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,962 $5,928
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $180/yr $1,804 $5,451
Estimated electricity spend (1,233 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for RELIANCE WATER HEATERS Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 3 brand-level recall notices associated with RELIANCE WATER HEATERS; match your serial plate before repair. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Certified Water Heaters Match 10-66-DHPTS 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to RELIANCE WATER HEATERS 10-66-DHPTS 2** by storage capacity and 3.7 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPS10-66H45DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
American HPS10266H045DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
Lochinvar HPSA065KD 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
State HPSX-66-DHPT 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
A. O. Smith HPSN10-66H45DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233

Which Home Setups Are NOT a Fit for RELIANCE WATER HEATERS 10-66-DHPTS 2**?

Comparing RELIANCE WATER HEATERS 10-66-DHPTS 2** against A. O. Smith HPS10-66H45DV 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • RELIANCE WATER HEATERS 10-66-DHPTS 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 10-66-DHPTS 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing RELIANCE WATER HEATERS 10-66-DHPTS 2** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPS10-66H45DV 2** footprint.

What Are the Key Questions About RELIANCE WATER HEATERS 10-66-DHPTS 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does RELIANCE WATER HEATERS 10-66-DHPTS 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; RELIANCE WATER HEATERS 10-66-DHPTS 2** logs 3.7 UEF (Pass: +1.20 / +48.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing RELIANCE WATER HEATERS 10-66-DHPTS 2**?

With a 61 in. height and 23 in. diameter, RELIANCE WATER HEATERS 10-66-DHPTS 2** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits RELIANCE WATER HEATERS 10-66-DHPTS 2**?

Powered via 240V at 22A max, RELIANCE WATER HEATERS 10-66-DHPTS 2** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for RELIANCE WATER HEATERS 10-66-DHPTS 2**?

Annual electric spend for RELIANCE WATER HEATERS 10-66-DHPTS 2** (1,233 kWh/yr) averages $224/yr nationwide (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing RELIANCE WATER HEATERS 10-66-DHPTS 2**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on RELIANCE WATER HEATERS 10-66-DHPTS 2**.

Is RELIANCE WATER HEATERS 10-66-DHPTS 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies RELIANCE WATER HEATERS 10-66-DHPTS 2** at 82 gal First Hour Rating (+10 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does RELIANCE WATER HEATERS have active CPSC SaferProducts notices affecting 10-66-DHPTS 2**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches RELIANCE WATER HEATERS 10-66-DHPTS 2** (3.7 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for RELIANCE WATER HEATERS 10-66-DHPTS 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks