Skip to main content
ENERGY STAR water heater model · PD 4470522

Eco-Logical OMNI-50HP2-1A Water Heater Specifications (4.23 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Eco-Logical OMNI-50HP2-1A achieves a certified 4.23 UEF rating across its 46-gallon nominal tank, 57 gal First Hour Rating and ranks #9 of 706 in its 706-model cohort (PD 4470522), recording Pass: +1.93 / +83.9% under 2029 DOE rules. Rated annual electricity draw of 769 kWh/yr equates to roughly $140/yr ($1,397 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-50H45DV 2** (3.8 UEF).

Uniform Energy Factor
4.23 UEF
Cohort UEF Rank
#9 of 706 (top 1.3%)
First Hour Rating
57 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.93 / +83.9%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Eco-Logical OMNI-50HP2-1A at 4.23 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Eco-Logical OMNI-50HP2-1A: 4.23
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Eco-Logical OMNI-50HP2-1A relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Eco-Logical OMNI-50HP2-1A logs 4.23 UEF and ranks #9 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Eco-Logical OMNI-50HP2-1A holds a +1.93 UEF (+83.9%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 769 kWh/yr for Eco-Logical OMNI-50HP2-1A runs ~$140/yr vs. ~$642/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Eco-Logical OMNI-50HP2-1A: 10-year operating spend spans $1,125 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,628 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Eco-Logical OMNI-50HP2-1A (4.23 UEF)? Check A. O. Smith HPS10-50H45DV 2** (3.8 UEF, delta -0.43) and American HPS10250H045DV 2** (3.8 UEF, delta -0.43).

How Complete Are the Certified Metrics for Eco-Logical OMNI-50HP2-1A?

Standing at #9 of 706 (top 1.3%) among 706 certified Hybrid/Electric Heat Pump heaters, Eco-Logical OMNI-50HP2-1A brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandEco-Logical6 certified listingsENERGY STAR PD 4470522
Model NumberOMNI-50HP2-1ADraw pattern: Medium-UsageOMNI-50HP2-1A
Uniform Energy Factor (UEF)4.23+0.53 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)57 gal-15 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use769 kWh/yr-303 kWh/yr vs. 1,072 kWh/yr medianEst. $140/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency484%+55.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)72.7" H x 16.1" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (16.1" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 18.5 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2025-07-04Certified 2025-07-04Markets: United States, Canada

What Is the Projected Utility Bill for OMNI-50HP2-1A by State?

At 769 kWh/yr, Eco-Logical OMNI-50HP2-1A averages about $140/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (769 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$140.00/yrHawaii$363.00/yrCalifornia$229.00/yrTexas$122.00/yrWashington$113.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $140/yr $1,397 $5,025
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $363/yr $3,628 $13,055
California 29.75 ¢/kWh ($0.2975) $229/yr $2,288 $8,232
Texas 15.91 ¢/kWh ($0.1591) $122/yr $1,223 $4,402
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $113/yr $1,125 $4,048
Estimated electricity spend (769 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Eco-Logical Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Eco-Logical in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to OMNI-50HP2-1A?

Ordered by minimal capacity and UEF spread relative to Eco-Logical OMNI-50HP2-1A, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPS10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (-0.43) 831
American HPS10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (-0.43) 831
Lochinvar HPSA050KD 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (-0.43) 831
RELIANCE WATER HEATERS 10-50-DHPTS 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (-0.43) 831
A. O. Smith HPSN10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (-0.43) 831

Who Is Eco-Logical OMNI-50HP2-1A Best For — and When Should You Pick A. O. Smith HPS10-50H45DV 2**?

Evaluate whether Eco-Logical OMNI-50HP2-1A's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Eco-Logical OMNI-50HP2-1A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Eco-Logical OMNI-50HP2-1A directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Eco-Logical OMNI-50HP2-1A Strong Fit — 4.23 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPS10-50H45DV 2** footprint.

Practical Specs & Code Questions for Eco-Logical OMNI-50HP2-1A

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Eco-Logical OMNI-50HP2-1A (4.23 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Eco-Logical OMNI-50HP2-1A records 4.23 UEF (Pass: +1.93 / +83.9%), placing #9 of 706 (top 1.3%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Eco-Logical OMNI-50HP2-1A fit inside a tight hallway closet or low-headroom utility room?

Eco-Logical OMNI-50HP2-1A requires room for its 72.7 in. vertical shell and 16.1 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (16.1" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Eco-Logical OMNI-50HP2-1A?

For Eco-Logical OMNI-50HP2-1A, plan a 240V circuit at 18.5A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Eco-Logical OMNI-50HP2-1A?

Using 769 kWh/yr, Eco-Logical OMNI-50HP2-1A generates an estimated $140/yr electric bill at 18.16 cents/kWh (ranging from $113/yr in Washington hydro tiers up to $363/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Eco-Logical OMNI-50HP2-1A (4.23 UEF)?

Eco-Logical OMNI-50HP2-1A requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPS10-50H45DV 2**.

What hot-water delivery rating governs Eco-Logical OMNI-50HP2-1A?

Rated for 57 gal FHR (-15 gal vs. 72 gal median), Eco-Logical OMNI-50HP2-1A prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Eco-Logical OMNI-50HP2-1A for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Eco-Logical; use our browser-only serial decoder to inspect Eco-Logical OMNI-50HP2-1A's age and warranty window.

What alternative models sit closest to Eco-Logical OMNI-50HP2-1A in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-50H45DV 2** (3.8 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks