Eco-Logical OMNI-50HP2-1A Water Heater Specifications (4.23 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Eco-Logical OMNI-50HP2-1A achieves a certified 4.23 UEF rating across its 46-gallon nominal tank, 57 gal First Hour Rating and ranks #9 of 706 in its 706-model cohort (PD 4470522), recording Pass: +1.93 / +83.9% under 2029 DOE rules. Rated annual electricity draw of 769 kWh/yr equates to roughly $140/yr ($1,397 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-50H45DV 2** (3.8 UEF).
- Uniform Energy Factor
- 4.23 UEF
- Cohort UEF Rank
- #9 of 706 (top 1.3%)
- First Hour Rating
- 57 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.93 / +83.9%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Eco-Logical OMNI-50HP2-1A logs 4.23 UEF and ranks #9 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Eco-Logical OMNI-50HP2-1A holds a +1.93 UEF (+83.9%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 769 kWh/yr for Eco-Logical OMNI-50HP2-1A runs ~$140/yr vs. ~$642/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Eco-Logical OMNI-50HP2-1A: 10-year operating spend spans $1,125 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,628 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Eco-Logical OMNI-50HP2-1A (4.23 UEF)? Check A. O. Smith HPS10-50H45DV 2** (3.8 UEF, delta -0.43) and American HPS10250H045DV 2** (3.8 UEF, delta -0.43).
How Complete Are the Certified Metrics for Eco-Logical OMNI-50HP2-1A?
Standing at #9 of 706 (top 1.3%) among 706 certified Hybrid/Electric Heat Pump heaters, Eco-Logical OMNI-50HP2-1A brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Eco-Logical | 6 certified listings | ENERGY STAR PD 4470522 |
| Model Number | OMNI-50HP2-1A | Draw pattern: Medium-Usage | OMNI-50HP2-1A |
| Uniform Energy Factor (UEF) | 4.23 | +0.53 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 57 gal | -15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 769 kWh/yr | -303 kWh/yr vs. 1,072 kWh/yr median | Est. $140/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 484% | +55.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 72.7" H x 16.1" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (16.1" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 18.5 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-04 | Certified 2025-07-04 | Markets: United States, Canada |
What Is the Projected Utility Bill for OMNI-50HP2-1A by State?
At 769 kWh/yr, Eco-Logical OMNI-50HP2-1A averages about $140/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $140/yr | $1,397 | $5,025 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $363/yr | $3,628 | $13,055 |
| California | 29.75 ¢/kWh ($0.2975) | $229/yr | $2,288 | $8,232 |
| Texas | 15.91 ¢/kWh ($0.1591) | $122/yr | $1,223 | $4,402 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $113/yr | $1,125 | $4,048 |
Are Eco-Logical Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched Eco-Logical in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to OMNI-50HP2-1A?
Ordered by minimal capacity and UEF spread relative to Eco-Logical OMNI-50HP2-1A, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPS10-50H45DV 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (-0.43) | 831 |
| American HPS10250H045DV 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (-0.43) | 831 |
| Lochinvar HPSA050KD 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (-0.43) | 831 |
| RELIANCE WATER HEATERS 10-50-DHPTS 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (-0.43) | 831 |
| A. O. Smith HPSN10-50H45DV 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (-0.43) | 831 |
Who Is Eco-Logical OMNI-50HP2-1A Best For — and When Should You Pick A. O. Smith HPS10-50H45DV 2**?
Evaluate whether Eco-Logical OMNI-50HP2-1A's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Eco-Logical OMNI-50HP2-1A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Eco-Logical OMNI-50HP2-1A directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Eco-Logical OMNI-50HP2-1A
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Eco-Logical OMNI-50HP2-1A (4.23 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Eco-Logical OMNI-50HP2-1A records 4.23 UEF (Pass: +1.93 / +83.9%), placing #9 of 706 (top 1.3%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Eco-Logical OMNI-50HP2-1A fit inside a tight hallway closet or low-headroom utility room?
Eco-Logical OMNI-50HP2-1A requires room for its 72.7 in. vertical shell and 16.1 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (16.1" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Eco-Logical OMNI-50HP2-1A?
For Eco-Logical OMNI-50HP2-1A, plan a 240V circuit at 18.5A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Eco-Logical OMNI-50HP2-1A?
Using 769 kWh/yr, Eco-Logical OMNI-50HP2-1A generates an estimated $140/yr electric bill at 18.16 cents/kWh (ranging from $113/yr in Washington hydro tiers up to $363/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Eco-Logical OMNI-50HP2-1A (4.23 UEF)?
Eco-Logical OMNI-50HP2-1A requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPS10-50H45DV 2**.
What hot-water delivery rating governs Eco-Logical OMNI-50HP2-1A?
Rated for 57 gal FHR (-15 gal vs. 72 gal median), Eco-Logical OMNI-50HP2-1A prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Eco-Logical OMNI-50HP2-1A for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Eco-Logical; use our browser-only serial decoder to inspect Eco-Logical OMNI-50HP2-1A's age and warranty window.
What alternative models sit closest to Eco-Logical OMNI-50HP2-1A in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-50H45DV 2** (3.8 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)