Skip to main content
ENERGY STAR water heater model · PD 4016265

GE Profile PF40S10FPY01 Water Heater Specifications (3.1 UEF)

The GE Profile PF40S10FPY01 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.1 UEF rating across its 40-gallon nominal tank, 46 gal First Hour Rating, ranking #664 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4016265). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.80 / +34.8%. Rated annual electricity draw of 724 kWh/yr equates to roughly $131/yr ($1,315 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-40-T (3.55 UEF).

Uniform Energy Factor
3.1 UEF
Cohort UEF Rank
#664 of 706
First Hour Rating
46 gal
Storage Volume
40 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.80 / +34.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking GE Profile PF40S10FPY01 at 3.1 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30GE Profile PF40S10FPY01: 3.10
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PF40S10FPY01 relative to the cohort median.
Efficiency comparison & rule summary

GE Profile PF40S10FPY01 (3.1 UEF) ranks #664 of 706 Hybrid/Electric Heat Pump models — 2-way tie; more efficient than 5.8% of Hybrid/Electric Heat Pump models, -0.60 UEF below the 3.70 UEF median.

Federal 2029 margin for GE Profile PF40S10FPY01: +0.80 UEF (+34.8%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 724 kWh/yr for GE Profile PF40S10FPY01 runs ~$131/yr vs. ~$443/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PF40S10FPY01: 10-year operating spend spans $1,059 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,416 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: GE Profile PF40S10FPY01 (3.1 UEF) compares closely with Ariston ARIHPWH-40-T (3.55 UEF, delta +0.45) and Lennox WHHP040T45MD240S**** (3.55 UEF, delta +0.45).

Which Specs Set GE Profile PF40S10FPY01 Apart From Cohort Averages?

Ranked #664 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, GE Profile PF40S10FPY01 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGE Profile18 certified listingsENERGY STAR PD 4016265
Model NumberPF40S10FPY01Draw pattern: Low-UsagePF40S10FPY01
Uniform Energy Factor (UEF)3.1-0.60 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)46 gal-26 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use724 kWh/yr-348 kWh/yr vs. 1,072 kWh/yr medianEst. $131/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency397%-32.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)39.4" H x 18.5" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 7.5 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR1234YFLower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level41 dBAtop 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-05-28Certified 2025-05-28Markets: United States

How Do Regional kWh Prices Impact PF40S10FPY01 Over 10 Years?

Using EIA Table 5.6.A benchmarks, GE Profile PF40S10FPY01's 724 kWh/yr draw translates to roughly $131/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (724 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$131.00/yrHawaii$342.00/yrCalifornia$215.00/yrTexas$115.00/yrWashington$106.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $131/yr $1,315 $3,116
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $342/yr $3,416 $8,096
California 29.75 ¢/kWh ($0.2975) $215/yr $2,154 $5,105
Texas 15.91 ¢/kWh ($0.1591) $115/yr $1,152 $2,730
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $106/yr $1,059 $2,511
Estimated electricity spend (724 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should GE Profile Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for GE Profile; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Ariston ARIHPWH-40-T Hybrid/Electric Heat Pump 37 gal 65 gal 3.55 (+0.45) 915
Lennox WHHP040T45MD240S**** Hybrid/Electric Heat Pump 37 gal 65 gal 3.55 (+0.45) 915
AMERICAN STANDARD WATER HEATERS ASHPWH-40***** Hybrid/Electric Heat Pump 37 gal 66 gal 3.58 (+0.48) 907
SANCO2 GS5-45HPC-D HP + ECO-43SSAQB Hybrid/Electric Heat Pump 43 gal 73 gal 3.7 (+0.60) 868
Ariston ARIHPWH-40 Hybrid/Electric Heat Pump 37 gal 66 gal 3.58 (+0.48) 907

What Are the Limitations of GE Profile PF40S10FPY01 and Who Should Not Install It?

Before ordering GE Profile PF40S10FPY01 (Hybrid/Electric Heat Pump, 3.1 UEF), weigh space clearances, fuel piping, noise (41 dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • GE Profile PF40S10FPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 41 dBA; avoid mounting GE Profile PF40S10FPY01 directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing GE Profile PF40S10FPY01 Strong Fit — 3.1 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Ariston ARIHPWH-40-T footprint.

Frequently Asked Technical Questions: GE Profile PF40S10FPY01

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does GE Profile PF40S10FPY01 pass the May 6, 2029 federal DOE efficiency rule?

GE Profile PF40S10FPY01 carries a verified 3.1 UEF rating (Pass: +0.80 / +34.8%), ranking #664 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does GE Profile PF40S10FPY01 need?

GE Profile PF40S10FPY01 stands 39.4 in. high with a 18.5 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does GE Profile PF40S10FPY01 require?

GE Profile PF40S10FPY01 uses a 120V branch circuit at 7.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does GE Profile PF40S10FPY01 cost per year to run?

Rated at 724 kWh/yr, GE Profile PF40S10FPY01 costs about $131/yr ($1,310 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $106/yr in Washington hydro tiers up to $342/yr in Hawaii).

Who should NOT install GE Profile PF40S10FPY01, and what are its limits?

GE Profile PF40S10FPY01 (3.1 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 41 dBA.

How many bathrooms or people can GE Profile PF40S10FPY01 serve at peak demand?

GE Profile PF40S10FPY01 achieves a 46 gal First Hour Rating (-26 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for GE Profile PF40S10FPY01?

No active CPSC recalls matched GE Profile as of 2026-11-23. Always decode the serial tag on GE Profile PF40S10FPY01 because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to GE Profile PF40S10FPY01, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-40-T (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks