GE Profile PJ40S10FPY01 Water Heater Specifications (3.1 UEF)
Certified at 3.1 UEF across its 40-gallon nominal tank, 46 gal First Hour Rating, GE Profile PJ40S10FPY01 (Hybrid/Electric Heat Pump, Electric) places #664 of 706 out of 706 ENERGY STAR models (PD 4016266). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.80 / +34.8%. Rated annual electricity draw of 724 kWh/yr equates to roughly $131/yr ($1,315 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-40-T (3.55 UEF).
- Uniform Energy Factor
- 3.1 UEF
- Cohort UEF Rank
- #664 of 706
- First Hour Rating
- 46 gal
- Storage Volume
- 40 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.80 / +34.8%

Tested at 3.1 UEF, GE Profile PJ40S10FPY01 places #664 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.60 UEF vs. 3.70 UEF median).
GE Profile PJ40S10FPY01 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +0.80 UEF (+34.8% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 724 kWh/yr for GE Profile PJ40S10FPY01 runs ~$131/yr vs. ~$443/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).
State electric sensitivity for GE Profile PJ40S10FPY01: 10-year operating spend spans $1,059 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,416 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to GE Profile PJ40S10FPY01 include Ariston ARIHPWH-40-T (3.55 UEF, delta +0.45) alongside Lennox WHHP040T45MD240S**** (3.55 UEF, delta +0.45).
How Complete Are the Certified Metrics for GE Profile PJ40S10FPY01?
Standing at #664 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, GE Profile PJ40S10FPY01 brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | GE Profile | 18 certified listings | ENERGY STAR PD 4016266 |
| Model Number | PJ40S10FPY01 | Draw pattern: Low-Usage | PJ40S10FPY01 |
| Uniform Energy Factor (UEF) | 3.1 | -0.60 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 46 gal | -26 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 724 kWh/yr | -348 kWh/yr vs. 1,072 kWh/yr median | Est. $131/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 397% | -32.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 39.4" H x 18.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 7.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-05-28 | Certified 2025-05-28 | Markets: Canada |
What Is the Projected Utility Bill for PJ40S10FPY01 by State?
At 724 kWh/yr, GE Profile PJ40S10FPY01 averages about $131/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $131/yr | $1,315 | $3,116 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $342/yr | $3,416 | $8,096 |
| California | 29.75 ¢/kWh ($0.2975) | $215/yr | $2,154 | $5,105 |
| Texas | 15.91 ¢/kWh ($0.1591) | $115/yr | $1,152 | $2,730 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $106/yr | $1,059 | $2,511 |
Are GE Profile Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched GE Profile in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to PJ40S10FPY01?
Ordered by minimal capacity and UEF spread relative to GE Profile PJ40S10FPY01, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Ariston ARIHPWH-40-T | Hybrid/Electric Heat Pump | 37 gal | 65 gal | 3.55 (+0.45) | 915 |
| Lennox WHHP040T45MD240S**** | Hybrid/Electric Heat Pump | 37 gal | 65 gal | 3.55 (+0.45) | 915 |
| AMERICAN STANDARD WATER HEATERS ASHPWH-40***** | Hybrid/Electric Heat Pump | 37 gal | 66 gal | 3.58 (+0.48) | 907 |
| SANCO2 GS5-45HPC-D HP + ECO-43SSAQB | Hybrid/Electric Heat Pump | 43 gal | 73 gal | 3.7 (+0.60) | 868 |
| Ariston ARIHPWH-40 | Hybrid/Electric Heat Pump | 37 gal | 66 gal | 3.58 (+0.48) | 907 |
When Should Homeowners Skip GE Profile PJ40S10FPY01 (Hybrid/Electric Heat Pump)?
Check GE Profile PJ40S10FPY01's mechanical constraints—including utility space, Electric capacity, and Pass: +0.80 / +34.8% status—against typical residential installations.
Key Limitations & Exclusions
- GE Profile PJ40S10FPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PJ40S10FPY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for GE Profile PJ40S10FPY01
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will GE Profile PJ40S10FPY01 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.1 UEF, GE Profile PJ40S10FPY01 shows Pass: +0.80 / +34.8% relative to May 6, 2029 federal DOE limits while placing #664 of 706 among 706 Hybrid/Electric Heat Pump peers like Ariston ARIHPWH-40-T.
Will GE Profile PJ40S10FPY01 fit through a standard utility door and 72-inch basement ceiling?
Measuring 39.4 in. tall by 18.5 in. diameter, GE Profile PJ40S10FPY01 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support GE Profile PJ40S10FPY01 during replacement?
Electrical specs for GE Profile PJ40S10FPY01 call for 120V at 7.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for GE Profile PJ40S10FPY01?
At 18.16 cents/kWh national residential pricing, GE Profile PJ40S10FPY01's 724 kWh/yr draw equals roughly $131 annually or $1,310 across a 10-year horizon (ranging from $106/yr in Washington hydro tiers up to $342/yr in Hawaii).
When is GE Profile PJ40S10FPY01 a poor fit for a residential replacement?
Avoid placing GE Profile PJ40S10FPY01 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 41 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does GE Profile PJ40S10FPY01 deliver?
With 46 gal FHR (-26 gal vs. 72 gal median), GE Profile PJ40S10FPY01 fits 1–3 person or moderate-draw homes cleanly.
How do you verify manufacturing age and recall status on GE Profile PJ40S10FPY01?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for GE Profile; verify exact manufacturing week for GE Profile PJ40S10FPY01 using the Serial Number Lookup tool.
Does GE Profile PJ40S10FPY01 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for GE Profile PJ40S10FPY01. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-40-T (3.55 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)