Rheem ECEPH65 T2 RH400-15 Water Heater Specifications (3.55 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Rheem ECEPH65 T2 RH400-15 (Electric) achieves a certified 3.55 UEF rating across its 59-gallon nominal tank, 54 gal First Hour Rating (rank #414 of 706, PD 4046759) and verifies as Pass: +1.05 / +42.0% for 2029 DOE floors. Rated annual electricity draw of 887 kWh/yr equates to roughly $161/yr ($1,611 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-15 (3.55 UEF).
- Uniform Energy Factor
- 3.55 UEF
- Cohort UEF Rank
- #414 of 706
- First Hour Rating
- 54 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.05 / +42.0%

Rheem ECEPH65 T2 RH400-15 records 3.55 UEF efficiency, putting it #414 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Rheem ECEPH65 T2 RH400-15 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.05 UEF (+42.0%). At EIA August 2026 national rates (18.16 cents/kWh), 887 kWh/yr for Rheem ECEPH65 T2 RH400-15 runs ~$161/yr vs. ~$622/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem ECEPH65 T2 RH400-15: 10-year operating spend spans $1,298 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,185 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Rheem ECEPH65 T2 RH400-15 (3.55 UEF) are Friedrich PROH65 T2 FD400-15 (3.55 UEF, at parity) and Richmond 10CE65-HP5U15 (3.55 UEF, at parity).
What Physical and Thermal Ratings Define Rheem ECEPH65 T2 RH400-15?
Positioning at #414 of 706 out of 706 Hybrid/Electric Heat Pump peers, Rheem ECEPH65 T2 RH400-15 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 4046759 |
| Model Number | ECEPH65 T2 RH400-15 | Draw pattern: Medium-Usage | ECEPH65 T2 RH400-15 |
| Uniform Energy Factor (UEF) | 3.55 | -0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 54 gal | -18 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 887 kWh/yr | -185 kWh/yr vs. 1,072 kWh/yr median | Est. $161/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
Why Do State Utility Rates Shift ECEPH65 T2 RH400-15 Running Costs?
Consuming 887 kWh annually puts Rheem ECEPH65 T2 RH400-15 near $161/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $161/yr | $1,611 | $4,605 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $418/yr | $4,185 | $11,965 |
| California | 29.75 ¢/kWh ($0.2975) | $264/yr | $2,639 | $7,545 |
| Texas | 15.91 ¢/kWh ($0.1591) | $141/yr | $1,411 | $4,035 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $130/yr | $1,298 | $3,710 |
Have Any Rheem Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to Rheem ECEPH65 T2 RH400-15?
Homeowners cross-shopping Rheem ECEPH65 T2 RH400-15 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| Richmond 10CE65-HP5U15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| Ruud PROUH65 T2 CD400-15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| A. O. Smith HPACO-45 1**+AXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.15) | 1,341 |
| Richmond 10E65-HP515 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
When Should Homeowners Skip Rheem ECEPH65 T2 RH400-15 (Hybrid/Electric Heat Pump)?
Check Rheem ECEPH65 T2 RH400-15's mechanical constraints—including utility space, Electric capacity, and Pass: +1.05 / +42.0% status—against typical residential installations.
Key Limitations & Exclusions
- Rheem ECEPH65 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem ECEPH65 T2 RH400-15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Rheem ECEPH65 T2 RH400-15
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Rheem ECEPH65 T2 RH400-15 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.55 UEF, Rheem ECEPH65 T2 RH400-15 shows Pass: +1.05 / +42.0% relative to May 6, 2029 federal DOE limits while placing #414 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH65 T2 FD400-15.
Will Rheem ECEPH65 T2 RH400-15 fit through a standard utility door and 72-inch basement ceiling?
Measuring 64.2 in. tall by 24.3 in. diameter, Rheem ECEPH65 T2 RH400-15 notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Rheem ECEPH65 T2 RH400-15 during replacement?
Electrical specs for Rheem ECEPH65 T2 RH400-15 call for 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Rheem ECEPH65 T2 RH400-15?
At 18.16 cents/kWh national residential pricing, Rheem ECEPH65 T2 RH400-15's 887 kWh/yr draw equals roughly $161 annually or $1,610 across a 10-year horizon (ranging from $130/yr in Washington hydro tiers up to $418/yr in Hawaii).
When is Rheem ECEPH65 T2 RH400-15 a poor fit for a residential replacement?
Avoid placing Rheem ECEPH65 T2 RH400-15 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Rheem ECEPH65 T2 RH400-15 deliver?
With 54 gal FHR (-18 gal vs. 72 gal median), Rheem ECEPH65 T2 RH400-15 fits 1–3 person or moderate-draw homes cleanly.
How do you verify manufacturing age and recall status on Rheem ECEPH65 T2 RH400-15?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does Rheem ECEPH65 T2 RH400-15 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rheem ECEPH65 T2 RH400-15. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-15 (3.55 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)