Rheem PROPH65 T2 RH400-15 Water Heater Specifications (3.55 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem PROPH65 T2 RH400-15 achieves a certified 3.55 UEF rating across its 59-gallon nominal tank, 54 gal First Hour Rating and ranks #414 of 706 in its 706-model cohort (PD 3554212), recording Pass: +1.05 / +42.0% under 2029 DOE rules. Rated annual electricity draw of 887 kWh/yr equates to roughly $161/yr ($1,611 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-15 (3.55 UEF).
- Uniform Energy Factor
- 3.55 UEF
- Cohort UEF Rank
- #414 of 706
- First Hour Rating
- 54 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.05 / +42.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem PROPH65 T2 RH400-15 logs 3.55 UEF and ranks #414 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rheem PROPH65 T2 RH400-15 holds a +1.05 UEF (+42.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 887 kWh/yr for Rheem PROPH65 T2 RH400-15 runs ~$161/yr vs. ~$622/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem PROPH65 T2 RH400-15: 10-year operating spend spans $1,298 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,185 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Rheem PROPH65 T2 RH400-15 (3.55 UEF)? Check Friedrich PROH65 T2 FD400-15 (3.55 UEF, at parity) and Richmond 10CE65-HP5U15 (3.55 UEF, at parity).
How Complete Are the Certified Metrics for Rheem PROPH65 T2 RH400-15?
Standing at #414 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Rheem PROPH65 T2 RH400-15 brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554212 |
| Model Number | PROPH65 T2 RH400-15 | Draw pattern: Medium-Usage | PROPH65 T2 RH400-15 |
| Uniform Energy Factor (UEF) | 3.55 | -0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 54 gal | -18 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 887 kWh/yr | -185 kWh/yr vs. 1,072 kWh/yr median | Est. $161/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Is the Projected Utility Bill for PROPH65 T2 RH400-15 by State?
At 887 kWh/yr, Rheem PROPH65 T2 RH400-15 averages about $161/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $161/yr | $1,611 | $4,605 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $418/yr | $4,185 | $11,965 |
| California | 29.75 ¢/kWh ($0.2975) | $264/yr | $2,639 | $7,545 |
| Texas | 15.91 ¢/kWh ($0.1591) | $141/yr | $1,411 | $4,035 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $130/yr | $1,298 | $3,710 |
Are Rheem Models Affected by Current CPSC Notices?
Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to PROPH65 T2 RH400-15?
Ordered by minimal capacity and UEF spread relative to Rheem PROPH65 T2 RH400-15, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| Richmond 10CE65-HP5U15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| Ruud PROUH65 T2 CD400-15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| A. O. Smith HPACO-45 1**+AXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.15) | 1,341 |
| Richmond 10E65-HP515 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
What Are the Limitations of Rheem PROPH65 T2 RH400-15 and Who Should Not Install It?
Before ordering Rheem PROPH65 T2 RH400-15 (Hybrid/Electric Heat Pump, 3.55 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Rheem PROPH65 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem PROPH65 T2 RH400-15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Rheem PROPH65 T2 RH400-15
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Rheem PROPH65 T2 RH400-15 pass the May 6, 2029 federal DOE efficiency rule?
Rheem PROPH65 T2 RH400-15 carries a verified 3.55 UEF rating (Pass: +1.05 / +42.0%), ranking #414 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Rheem PROPH65 T2 RH400-15 need?
Rheem PROPH65 T2 RH400-15 stands 64.2 in. high with a 24.3 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Rheem PROPH65 T2 RH400-15 require?
Rheem PROPH65 T2 RH400-15 uses a 240V branch circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Rheem PROPH65 T2 RH400-15 cost per year to run?
Rated at 887 kWh/yr, Rheem PROPH65 T2 RH400-15 costs about $161/yr ($1,610 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $130/yr in Washington hydro tiers up to $418/yr in Hawaii).
Who should NOT install Rheem PROPH65 T2 RH400-15, and what are its limits?
Rheem PROPH65 T2 RH400-15 (3.55 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Rheem PROPH65 T2 RH400-15 serve at peak demand?
Rheem PROPH65 T2 RH400-15 achieves a 54 gal First Hour Rating (-18 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Rheem PROPH65 T2 RH400-15?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Rheem PROPH65 T2 RH400-15, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-15 (3.55 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)