Skip to main content
ENERGY STAR water heater model · PD 3462860

Rinnai REHP50BM Water Heater Specifications (3.75 UEF)

The Rinnai REHP50BM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.75 UEF rating across its 46-gallon nominal tank, 73 gal First Hour Rating, ranking #297 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3462860). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.45 / +63.0%. Rated annual electricity draw of 844 kWh/yr equates to roughly $153/yr ($1,533 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Midea CAN3-RSJ-15/190RDVN3-L4 (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
73 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rinnai REHP50BM at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Rinnai REHP50BM: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rinnai REHP50BM relative to the cohort median.
Efficiency comparison & rule summary

Rinnai REHP50BM (3.75 UEF) ranks #297 of 706 Hybrid/Electric Heat Pump models — 48-way tie; more efficient than 51.3% of Hybrid/Electric Heat Pump models, +0.05 UEF above the 3.70 UEF median.

Federal 2029 margin for Rinnai REHP50BM: +1.45 UEF (+63.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 844 kWh/yr for Rinnai REHP50BM runs ~$153/yr vs. ~$625/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Rinnai REHP50BM: 10-year operating spend spans $1,235 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,982 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Rinnai REHP50BM (3.75 UEF) compares closely with Midea CAN3-RSJ-15/190RDVN3-L4 (3.75 UEF, at parity) and A. O. Smith HPS10-50H45DV 2** (3.8 UEF, delta +0.05).

Which Specs Set Rinnai REHP50BM Apart From Cohort Averages?

Ranked #297 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Rinnai REHP50BM is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRinnai25 certified listingsENERGY STAR PD 3462860
Model NumberREHP50BMDraw pattern: Medium-UsageREHP50BM
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)73 gal+1 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use844 kWh/yr-228 kWh/yr vs. 1,072 kWh/yr medianEst. $153/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency465%+36.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)66.4" H x 21.7" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (21.7" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-03-24Certified 2026-03-24Markets: United States, Canada

How Do Regional kWh Prices Impact REHP50BM Over 10 Years?

Using EIA Table 5.6.A benchmarks, Rinnai REHP50BM's 844 kWh/yr draw translates to roughly $153/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (844 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$153.00/yrHawaii$398.00/yrCalifornia$251.00/yrTexas$134.00/yrWashington$123.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $153/yr $1,533 $4,714
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $398/yr $3,982 $12,248
California 29.75 ¢/kWh ($0.2975) $251/yr $2,511 $7,723
Texas 15.91 ¢/kWh ($0.1591) $134/yr $1,343 $4,130
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $123/yr $1,235 $3,798
Estimated electricity spend (844 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Rinnai Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Rinnai; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Midea CAN3-RSJ-15/190RDVN3-L4 Hybrid/Electric Heat Pump 46 gal 71 gal 3.75 (at parity) 861
A. O. Smith HPS10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
American HPS10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
Lochinvar HPSA050KD 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (+0.05) 831
Midea MAHW-50VN3B Hybrid/Electric Heat Pump 46 gal 71 gal 3.75 (at parity) 861

When Should Homeowners Skip Rinnai REHP50BM (Hybrid/Electric Heat Pump)?

Check Rinnai REHP50BM's mechanical constraints—including utility space, Electric capacity, and Pass: +1.45 / +63.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Rinnai REHP50BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rinnai REHP50BM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rinnai REHP50BM Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Midea CAN3-RSJ-15/190RDVN3-L4 footprint.

Frequently Asked Technical Questions: Rinnai REHP50BM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Rinnai REHP50BM stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.75 UEF, Rinnai REHP50BM shows Pass: +1.45 / +63.0% relative to May 6, 2029 federal DOE limits while placing #297 of 706 among 706 Hybrid/Electric Heat Pump peers like Midea CAN3-RSJ-15/190RDVN3-L4.

Will Rinnai REHP50BM fit through a standard utility door and 72-inch basement ceiling?

Measuring 66.4 in. tall by 21.7 in. diameter, Rinnai REHP50BM notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (21.7" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Rinnai REHP50BM during replacement?

Electrical specs for Rinnai REHP50BM call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Rinnai REHP50BM?

At 18.16 cents/kWh national residential pricing, Rinnai REHP50BM's 844 kWh/yr draw equals roughly $153 annually or $1,530 across a 10-year horizon (ranging from $123/yr in Washington hydro tiers up to $398/yr in Hawaii).

When is Rinnai REHP50BM a poor fit for a residential replacement?

Avoid placing Rinnai REHP50BM directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Rinnai REHP50BM deliver?

With 73 gal FHR (+1 gal vs. 72 gal median), Rinnai REHP50BM fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Rinnai REHP50BM?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Rinnai; verify exact manufacturing week for Rinnai REHP50BM using the Serial Number Lookup tool.

Does Rinnai REHP50BM qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rinnai REHP50BM. Closest peer in Hybrid/Electric Heat Pump is Midea CAN3-RSJ-15/190RDVN3-L4 (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks