Skip to main content
ENERGY STAR water heater model · PD 2408852

A. O. Smith HPTS-66 2** Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, A. O. Smith HPTS-66 2** achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 2408852), recording Pass: +1.20 / +48.0% under 2029 DOE rules. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPS10266H045DV 2** (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
82 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPTS-66 2** at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPTS-66 2**: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTS-66 2** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, A. O. Smith HPTS-66 2** logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), A. O. Smith HPTS-66 2** holds a +1.20 UEF (+48.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for A. O. Smith HPTS-66 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPTS-66 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping A. O. Smith HPTS-66 2** (3.7 UEF)? Check American HPS10266H045DV 2** (3.7 UEF, at parity) and Lochinvar HPSA065KD 2** (3.7 UEF, at parity).

How Complete Are the Certified Metrics for A. O. Smith HPTS-66 2**?

Standing at #347 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, A. O. Smith HPTS-66 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2408852
Model NumberHPTS-66 2**Draw pattern: High-UsageHPTS-66 2**
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,233 kWh/yr+161 kWh/yr vs. 1,072 kWh/yr medianEst. $224/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency425%-4.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States, Canada

What Is the Projected Utility Bill for HPTS-66 2** by State?

At 1,233 kWh/yr, A. O. Smith HPTS-66 2** averages about $224/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,233 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$224.00/yrHawaii$582.00/yrCalifornia$367.00/yrTexas$196.00/yrWashington$180.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $224/yr $2,239 $6,766
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $582/yr $5,817 $17,579
California 29.75 ¢/kWh ($0.2975) $367/yr $3,668 $11,085
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,962 $5,928
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $180/yr $1,804 $5,451
Estimated electricity spend (1,233 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are A. O. Smith Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for A. O. Smith and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to HPTS-66 2**?

Ordered by minimal capacity and UEF spread relative to A. O. Smith HPTS-66 2**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPS10266H045DV 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
Lochinvar HPSA065KD 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
RELIANCE WATER HEATERS 10-66-DHPTS 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
State HPSX-66-DHPT 2** Hybrid/Electric Heat Pump 67 gal 82 gal 3.7 (at parity) 1,233
American HPHE10266H045DVCTA-1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (-0.25) 1,381

What Installation Caveats Apply Before Buying A. O. Smith HPTS-66 2**?

Even high-UEF units like A. O. Smith HPTS-66 2** (3.7 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • A. O. Smith HPTS-66 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTS-66 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPTS-66 2** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPS10266H045DV 2** footprint.

Practical Specs & Code Questions for A. O. Smith HPTS-66 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is A. O. Smith HPTS-66 2** eligible for continued manufacture past May 6, 2029?

At 3.7 UEF, A. O. Smith HPTS-66 2** achieves Pass: +1.20 / +48.0% for the 2029 DOE standard and stands #347 of 706 against American HPS10266H045DV 2** and Lochinvar HPSA065KD 2**.

How tall and wide is A. O. Smith HPTS-66 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith HPTS-66 2** are 61 in. height and 23 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d)); verify stair turns and drain pan width before delivery.

Will A. O. Smith HPTS-66 2** require upgrading household electrical panels or gas piping?

A. O. Smith HPTS-66 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is A. O. Smith HPTS-66 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $224/yr ($2,240 over 10 years) to power A. O. Smith HPTS-66 2** at 1,233 kWh/yr under the 18.16 cents/kWh US average (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii).

Which installation bottlenecks limit A. O. Smith HPTS-66 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith HPTS-66 2** drops into resistance mode more often.

How does A. O. Smith HPTS-66 2** handle simultaneous showers and laundry?

Delivering 82 gal in the first hour (+10 gal vs. 72 gal median), A. O. Smith HPTS-66 2** combines 67 gal tank storage with rapid burner/element recovery.

How long is the warranty on A. O. Smith HPTS-66 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying A. O. Smith HPTS-66 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPS10266H045DV 2** (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks